BZPZL - AMICURE BDMA CURING AGENT, HBDMAU
- MSDS: BZPZL
- Manufacturer: AIR PRODUCTS AND CHEMICALS INC
- Product Name: AMICURE BDMA CURING AGENT, HBDMAU
- National Stock Number: 8030-00N064414
Product Identification
Product ID:AMICURE BDMA CURING AGENT, HBDMAU
MSDS Date:10/01/1994
FSC:8030
NIIN:00N064414
MSDS Number: BZPZL
Responsible Party
ALLENTOWN, PA 18195-1501
US
Emergency Phone: 800-523-9374
Info Phone: 800-345-3148
Cage: 00742
Contractor
Telephone: 800-345-3148/ 800-752-1597
Cage: 00742
Ingredients
BENZYLAMINE, N,N-DIMETHYL-; (BENZYL DIMETHYLAMINE)
CAS: 103-83-3
RTECS: DP4500000
OSHA PEL N/K
ACGIH TLV: N/K
EFTS (SUCH AS COUGH, TIGHTNESS OF
RTECS: 9999999ZZ
RASH, IRRIT/CORR), ADVERSE EYE EFTS (SUCH AS
RTECS: 9999999ZZ
FRESH AIR & CALL MD. KEEP PATIENT
RTECS: 9999999ZZ
IF BRTHG HAS STOPPED/IS LABORED GIVE ASSISTED RESP
RTECS: 9999999ZZ
IF SWALLOWED CALL MD IMMED. REMOVE STOM
RTECS: 9999999ZZ
BY MED PERS. NEVER GIVE ANYTHING BY MOUTH TO UNCON
RTECS: 9999999ZZ
TISS SIMILAR TO THAT OF AMMONIA/AMMONIA GAS. CHEM
RTECS: 9999999ZZ
OF AIRWAY/OTHER AFFECTED TISS MAY OCCUR FOLLOWING
RTECS: 9999999ZZ
MANAGEMENT IS BASED ON SUPPORTIVE TREATMENT WHICH IS
RTECS: 9999999ZZ
SPRAY. CLEAN-UP PERS MUST BE EQUIPPED
RTECS: 9999999ZZ
PROD FROM ENTERING STREAMS/DRINKING WATER SUPPLIES.
RTECS: 9999999ZZ
SUCH CONTAM SHOULD OCCUR. POTENTIAL FOR CARBON
RTECS: 9999999ZZ
ON QUALITY & QTY OF WASTE TO BE TREATED,
RTECS: 9999999ZZ
STANDARDS. DISPOSE OF IN AN APPROVED LANDFILL IF
RTECS: 9999999ZZ
SITUATIONS WEAR IMPERMEABLE GLOVES WITH CUFFS
RTECS: 9999999ZZ
END OF EACH WORKSHIFT & BEFORE EATING,
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:LD50 (ORAL RAT): 265 MG/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: CONT OF UNDILUTED PROD
W/EYES/SKIN QUICKLY CAUSES SEV IRRIT & PAIN & MAY CAUSE BURNS,
NECROSIS & PERM INJURY. BURNS OF EYE MAY CAUSE BLINDNESS. INHAL OF
VAPS MAY SEV DMG TISS & ORGANS OF RESP T RACT W/POSS FATAL RSLT.
INGEST MAY CAUSE HDCH, VOMIT, DEATH UNLESS TREATED PROMPTLY. PROD
VAP IN LOW (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: CONCS CAN CAUSE LACRIMATION, CONJUNC
& CORNEAL EDEMA WHEN ABSORBED INTO TISS OF EYE FROM ATM. CORNEAL
EDEMA MAY GIVE RISE TO PERCEPTION OF "BLUE HAZE"/"FOG" AROUND
LIGHTS. EFT IS TRANSIENT & HAS NO KNOWN RESIDUAL EFT. EFTS FROM
INHAL OF VAPS MAY BE DELAYED. RPTD &/PRLNG EXPOS MAY RSLT IN
ADVERSE RESP (ING 2)
Medical Cond Aggravated by Exposure:ASTHMA. CHRONIC RESPIRATORY DISEASE
(E.G. BRONCHITIS, EMPHYSEMA), EYE DISEASE, SKIN DISORDERS AND
ALLERGIES.
First Aid
First Aid:EYE: HOLD EYELIDS APART & IMMED FLUSH W/PLENTY OF WATER FOR
AT LEAST 15 MIN. CALL MD. SKIN: REMOVE PROD & IMMED FLUSH AFFECTED
AREA W/WATER FOR AT LEAST 15 MIN. EXCEPT IN MOST MINOR, SUPERFICIAL
& LOC ALIZED BURNS, COVER AFFECTED AREA W/STERILE DRESSING/CLEAN
SHEETING & TRANSPORT FOR MED CARE. DO NOT APPLY GREASES/OINTMENTS.
CTL SHOCK IF PRESENT. CALL MD. INHAL: MOVE PATIENT AT ONCE TO (ING
4)
Fire Fighting
Flash Point Method:CC
Flash Point:129F,54C
Extinguishing Media:IGNITION WILL GIVE RISE TO A CLASS B FIRE. IN CASE
OF FIRE USE WATER SPRAY, CARBON DIOXIDE, DRY CHEMICAL, ALCOHOL
FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. RETAIN EXPENDED LIQS FROM FIRE FIGHT FOR LATER DISP. WATER SPRAY
IS ALSO USEFUL IN COOLING (SUP DAT)
Unusual Fire/Explosion Hazard:MAY GENERATE TOXIC OR IRRITATING
COMBUSTION PRODUCTS. SUDDEN REACTION AND FIRE MAY RESULT IF PRODUCT
IS MIXED WITH AN OXIDIZING AGENT.
Accidental Release
Spill Release Procedures:STOP LEAK IF POSS. VENT SPACE INVOLVED. SHUT
OFF/REMOVE ALL IGNIT SOURCES. CONSTRUCT DIKE TO PVNT SPREADING. IF
RECOVERY IS NOT FEASIBLE. ADMIX W/DRY SOIL, SAND/NON-REACTIVE
ABSORB & PLACE IN CONTR/DU MPSTER PENDING DISP. FLUSH AREA
W/WATER(ING 11)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP AWAY FROM OXIDIZERS/HEAT/FLAMES.
KEEP IN COOL, DRY, VENT STOR & IN CLSD CONTRS. STORE AWAY FROM
IGNIT SOURCES. GROUND ALL CONTRS DURING TRANSFER.
Other Precautions:AVOID CONT W/SKIN/EYES. AVOID BRTHG OF VAPS. HANDLE
IN WELL-VENT WORK SPACE. SMKNG IN AREA IS PROHIBITED. REMOVE ALL
EQUIP WHICH MAY BE SOURCE OF IGNIT FROM VICINITY WHILE HNDLG. WHEN
HNDLG DO NOT EAT , DRINK/SMOKE.
Exposure Controls
Respiratory Protection:IN POORLY VENTILATED AREAS, A CARTRIDGE MASK
NIOSH/MSHA APPROVED FOR ORGANIC VAPORS IS RECOMMENDED.
Ventilation:ADEQUATE GENERAL AND LOCAL EXHAUST. MAINTAIN AIR
CONCENTRATIONS IN WORK SPACES IN ACCORDANCE WITH STANDARDS
INDICATED.
Protective Gloves:NITRILE RUBBER GLOVES. IN EMER (ING 16)
Eye Protection:ANSI APPROVED CHEMICAL WORKERS (SUP DAT)
Other Protective Equipment:APPROP PROT CLTHG (SLICKER SUIT, RUBB
BOOTS). ANSI APPRVD EMER EYEWASH & DELUGE SHOWER .
Work Hygienic Practices:ADHERE TO WORK PRACT RULES ESTABLISED BY
GOVERMENT REGS (E.G. OSHA). CONT LENSES SHOULD NOT BE WORN. WASH AT
(ING 17)
Supplemental Safety and Health
FIRE FIGHT PROC: FIRE-EXPOS TANKS & IN DISPERSING VAPS. HAZ DECOMP
PROD: TO FORM CORR NITRIC ACID (TLV=2 PPM). COMBUST OF PROD UNDER
OXYGEN-STARVED CNDTNS CAN BE EXPECTED TO PRODUCE NUMEROUS TOX PRODS
INCL NITRILES, AMIDES. IRRIT & TOC FUMES AT ELEVATED TEMPS. EYE
PROT: GOGGLES AND FULL LENGTH FACESHIELD .
Chemical Properties
Boiling Pt:B.P. Text:360F,182C
Melt/Freeze Pt:M.P/F.P Text:-103F,-75C
Vapor Pres:1.8 @ 77F
Vapor Density:4.7
Spec Gravity:0.900 (H*2O=1)
pH:ALKALI
Evaporation Rate & Reference:<1 (BUTYL ACETATE=1)
Solubility in Water:SLIGHT
Appearance and Odor:COLORLESS MOBILE LIQUID, WITH AMMONIACAL ODOR
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS (PERCHLORATES/NITRATES, ETC), CLEANING SOLNS SUCH AS
CHROMERGE (SULFURIC ACID/DICHROMATE) & AQUA REGIA.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE/DIOXIDE & NITROGEN
OXIDES IN FIRE. AMMONIA WHEN HEATED. NITROGEN OXIDE CAN REACT
W/WATER VAPS (SUP DAT)
Disposal
Waste Disposal Methods:COMPLY W/ALL FED, STATE & LOC REGS. INCIN IN
ADMIXTURE W/FUEL EQUIPPED W/SCRUBBER TO REMOVE NITROGEN OXIDES &
CARBON MONOXIDE. CHEM &/BIOLOGICAL DEGRADATION IS FEASIBLE.
SUITABLE INDUSTRIAL/MUNICIPAL WASTE TREATMENT SYS CAN BE USED
DEPENDING (ING 14)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.